AGM Batteries

LP-General Use Series

lp-battery

General Features

  • Using oxygen recombination technology: maintenance-free
  • PbCaSn alloy for plate grids: less gassing, less self-discharging
  • High quality AGM separator: extend cycle life and prevent micro short circuit
  • ABS material: increase the strength of battery container. (Flame-retardant ABS is optional);
  • High purity raw material: ensure low self discharge rate
  • Silver-coated copper terminals (T1, T2 terminal), brass insert terminals and lead terminals improve the electric conductivity

Typical Applications

Small size
1.All purpose 2.Uninterruptable Power Supply (UPS) 3.Electric Power System (EPS)
4.Emergency light 5.Emergency backup power supply 6.Auto control system
7.Aircraft signal 8.Alarm and security system 9.Electronic apparatus and equipment
10.DC power supply 11.Communication power supply
2V Series

1.Tele-communication central station (wired or cellular)
2.Power system communication
3.Network communication including: data transmission, television signal transmission, etc.
4.Uninterruptable Power System (UPS- for Telecom)

Specifications

Model Nominal
Voltage
(V)
 
Rated CapacityAH Approx Dimension Approx
Weight
Terminal
type
20HR 10HR 5HR 1HR Length Width Height Total Height
1.80
V/cell
1.80
V/cell
1.75
V/cell
1.60
V/cell
mm in. mm in. mm in. mm in. kg lbs
LP4-3.5 4 3.50 3.26 2.94 2.12 90 3.54 34.0 1.34 59.0 2.32 65.0 2.56 0.45 0.99 T1
LP4-4.5 4 4.50 4.19 3.78 2.73 52.5 2.07 48.0 1.89 94.0 3.70 100.0 3.94 0.60 1.32 T1
LP4-5.0 4 5.00 4.65 4.20 3.04 91 3.58 50.0 1.97 74 2.91 74.0 2.91 0.66 1.46 T1
LP4-8.0 4 8.00 7.44 6.80 5.02 91 3.58 50.0 1.97 101 3.98 101.0 3.98 0.97 2.14 T2
LP4-10 4 10.0 9.30 8.50 6.28 101.5 4.00 50.0 1.97 94 3.70 100.0 3.94 1.14 2.51 T2
LP6-1.0 6 1.00 0.93 0.84 0.607 51 2.01 42.0 1.65 51 2.01 57.0 2.24 0.25 0.55 T1
LP6-1.2 6 1.20 1.12 1.01 0.728 97 3.82 24.0 0.94 51.5 2.03 57.5 2.26 0.29 0.64 T1
LP6-2.0 6 2.00 1.86 1.68 1.21 43 1.69 24.0 1.46 76.0 2.99 76.0 2.99 0.34 0.75 /
LP6-2.8 6 2.80 2.60 2.35 1.70 66 2.60 33.0 1.30 97.0 3.82 103.0 4.06 0.57 1.26 T1
LP6-3.2 6 3.20 2.98 2.69 1.94 134 5.28 34.0 1.34 60.0 2.36 66.0 2.60 0.67 1.48 T1
LP6-4.0 6 4.00 3.72 3.36 2.43 70 2.76 47.0 1.85 100.0 3.94 106.0 4.17 0.74 1.63 T1
LP6-4.0H 6 4.00 3.72 3.36 2.43 70 2.76 47 1.85 100 3.94 106 4.17 0.73 1.61 T1
LP6-4.5 6 4.50 4.19 3.78 2.73 70 2.76 47.0 1.85 100.0 3.94 106.0 4.17 0.81 1.79 T1
LP6-4.5H 6 4.50 4.19 3.78 2.73 70 2.76 47 1.85 100 3.94 106 4.17 0.75 1.65 T1
LP6-4.5S 6 4.50 4.19 3.78 2.73 67 2.64 67.0 2.64 96.0 3.78 109.0 4.29 0.81 1.79 S
LP6-5.0 6 5.00 4.65 4.20 3.04 169 6.65 35.0 1.38 70.0 2.76 74.0 2.91 0.95 2.09 T1
LP6-5.4 6 5.40 5.02 4.53 3.28 70 2.76 47.0 1.85 100.0 3.94 106.0 4.17 0.80 1.76 T1
LP6-6.0 6 6.00 5.58 5.05 3.64 70 2.76 47.0 1.85 100.0 3.94 106.0 4.17 0.88 1.94 T1

Curve Picture
lp qu

agm
XPE Series batteries incorporate advanced VRLA &COS technology designed for ultra high rate performance in UPS & power supply applications with 10 years design life at 25℃ ambient temperature. By using expending grid and specific paste plate to insure extra durable stable performance under high rate discharge.

General Features

  • Valve Regulated Lead Acid (VRLA) Battery,Maintenance Free (no topping up)
  • Absorbent Glass Mat (AGM) Separators technology for high efficiency, gas absorption of up to 98%
  • Mechanized production, COS technology, good conformance
  • No restrictions for rail, road, sea & air transport -Complies with IATA/ICAO Special Provisions A67
  • Special designed grids for optimized high power density
  • Advanced lead tin calcium alloy, reduces grid corrosion & promotes long battery life
  • Oversized partition intercell welds, providing low resistance connections & minimal power loss
  • Performance excels at high rates of discharge & recharge
  • High integrity post seal for long life
  • Vent Valve – allows the release of excess gases & prevents case rupture
  • Design according with IEC 60896-21/22:2004, JIS C 8704-2, GB/T 19638.2, etc.

Typical Applications

  • UPS (High rate)
  • Emergency power supply
  • Banks & Financial Markets
  • Hospitals & Testing Laboratories
  • Industrial Process Control Facilities
  • Date & Network Operations Centers

Specifications

Model Nominal
Voltage
(V)
Rated Capacity Approx
Weight
(Kg)
Approx Dimension(mm) Internal
Resistance
(ohm)
Terminal
Type
15min(W/cell)
1.67V/cell
10HR(Ah)
1.80V/cell
L W H TH
XPE12-125 12 130 38 11.4 197 165 170 170 10 T6/T10
XPE12-225 12 225 65 19 348 167 178 178 7 T6/T10
XPE12-350 12 350 80 23.5 330 173 212 212 5 T10
XPE12-400 12 400 100 28.5 410 177 225 225 4.5 T10

Curve Picture
XPE-UPS

Grid Tie Solar System

This system is for energy saving only, reduces electricity bill, NOT FOR BACK-UPs

Read More

Hybird Solar System

Our hybrid system work on both solar and grid electricity.During daytime, the loads are opered by solar energy.

Read More

Stand Alone Solar System

Living in a remote area where mains electricity Just isn't available or terribly cost prohibitive? Consider a stand alone solar power system.

Read More